MIL-G-47316A (MI)
d. Calculate apparent density as follows:
Apparent density, lbs/in3 = M
V
Where:
M = weight of sample, pounds
V = volume of sample, cubic inches
e. Report the apparent density of each block or billet in the lot.
4.6.3 Specific resistance. Specific resistance shall be determined in
accordance with the following to determine conformance to 3.3.2:
a. Assemble specific resistance testing apparatus as shown in figure 2.
FIGURE 2. Specific resistance test arrangement.